70mm Weepa

View installation guides

Product Overview

  • For use in rendered lightweight panel or kiwi brick.
  • Great ventilation and drainage of the cavity reduce fungal decay and mildew.
  • Pests are kept out!
  • The green mortar protector is removed after installation, leaving a clean and beautiful finish.
Std Weepa 2 sizes
70STD Weepa
Download installation guide

Installation guides

Download Installation Guide

Weepas in Masonry

Step 1 Standard Masonry

Step 1

Install the Weepa between bricks or blocks, at specified intervals and firmly in contact with the flashing. For rendering, set out a few millimetres.

Step 2 Standard Masonry

Step 2

When rendering, the Weepa needs to be loosened in the masonry so the renderer can adjust the Weepa in and out. Grab internal rib to adjust Weepa in and out.

Step 3 Standard Masonry

Step 3

After clean up, use a small, flat screwdriver to prise the mortar cover up at the bottom.

Step 4 Standard Masonry

Step 4

Close the grate assembly for an attractive and vermin proof weep hole.


Weepas in Rendered Masonry

Step 1 Standard Render

Step 1

Make sure the Weepa is installed when the masonry wall is built.

Step 2 Standard Render

Step 2

Loosen the Weepa and pull out proud of masonry.

Step 3 Standard Render

Step 3

Lay on render around the Weepa.

Step 4 Standard Render

Step 4

Screed off around the Weepa.

Step 5 Standard Render

Step 5

Pat the Weepa flush with the surface.

Step 6 Standard Render

Step 6

Float around the Weepa.

Step 7 Standard Render

Step 7

Sponge finish.
For easy removal later, wipe the mortar guard clean now, then again after painting.

Step 6 Standard Render

Step 8

After finish and cleanup remove the mortar guard for beautiful weepholes.


Weepas in Rendered Lightweight Panel

Step1 Standard Panel

Step 1

Mark the outline of the weep hole on each board at recommended centres and between each batten, then cut out with a jab saw.

Step2 Standard Panel

Step 2

Fix board as recommended by supplier.
Attention: Weepa does not encourage cutting out weep hole after fixing as this could compromise the waterproof membrane.

Step3 Standard Panel

Step 3

Check Weepa depth at back to ensure adequate clearance of studs and flashing.
Ventilation must not be impeded

Step4 Standard Panel

Step 4

If necessary, cut the back off the Weepa and remove dags.

Step5 Standard Panel

Step 5

Apply recommended glue to Weepa and push into weep hole slot so it acts as formwork for coating or finish.
Smooth off excess glue. Allow to dry.

Step6 Standard Panel

Step 6

Apply render or coating.
Screed as desired.

Step7 Standard Panel

Step 7

Sponge as required. Clean the Weepa cover of excess render, finish and paint at each stage.

Step8 Standard Panel

Step 8

After final finish and clean up remove cover.
End result: beautiful and functional Weepa weep holes!


< Back to product overview

The Weepa range is subject to Intellectual Property Rights: Aust Pat Nos - 713335, 762230, 2007237177, 2007215369, 2008271915  Aust Pat Aps - 2013211506. International PCT AU2007/000004, PCT AU2014/000123.  NZ Pat No 567674, Sth Africa Pat No 2008/03841, USA Pat No 8171677, Canada Pat No 2629033, Germany Pat No 602007037097.3, Spain Pat No ES2491221, Italy Pat No IT1984580, France Pat No FR1984580, United Kingdom Pat No GB1984580. Des Reg 137021, 150609, 156915. Aust TM 775282, NZ TM 961710, USA TM 4457028, Europe TM 1145302.